Coleman Evcon Furnace Troubleshooting: Expert Tips & Solutions

To troubleshoot a Coleman Evcon furnace, check the thermostat settings and ensure the power supply is active. Inspect the air filter and blower motor for blockages.

A malfunctioning furnace can be frustrating, especially during colder months. Coleman Evcon furnaces are known for their reliability, but issues can still arise. Regular maintenance and timely troubleshooting are crucial for optimal performance. Common problems include incorrect thermostat settings, a tripped circuit breaker, or a clogged air filter.

Addressing these issues promptly can prevent more serious complications. Regularly inspecting and cleaning your furnace ensures it runs efficiently, providing consistent warmth. If problems persist, consulting a professional technician may be necessary. Proper care extends the life of your furnace, ensuring comfort and safety in your home.

Coleman Evcon Furnace Troubleshooting: Expert Tips & Solutions

Credit: colemanhvacparts.com

Common Issues

The Coleman Evcon furnace is known for its reliability. But, like any appliance, it can face some common issues. Knowing these problems can help you fix them quickly. Below are some frequent issues you might encounter.

No Heat

One of the most reported issues is the furnace not producing heat. This can be due to various reasons:

  • Thermostat settings: Ensure the thermostat is set to “Heat”.
  • Power supply: Check if the furnace is receiving power. Look at the circuit breaker and the power switch.
  • Pilot light: Verify if the pilot light is on. If not, you may need to relight it.
  • Gas valve: Make sure the gas valve is open. This is crucial for gas furnaces.

If the furnace still produces no heat, call a technician.

Blower Issues

Blower problems can disrupt your heating system. Here are some common blower issues and their fixes:

Issue Possible Cause Solution
Blower runs constantly Thermostat fan set to “On” Set thermostat fan to “Auto”
No air from vents Blower motor failure Inspect and replace the motor
Strange noises Loose or damaged parts Tighten or replace parts

Regular maintenance can prevent many blower issues.

Coleman Evcon Furnace Troubleshooting: Expert Tips & Solutions

Credit: www.shareyourrepair.com

Initial Checks

When experiencing issues with your Coleman Evcon furnace, start with some initial checks. These simple steps might resolve common problems. Before calling a professional, go through these checks to potentially save time and money.

Thermostat Settings

The thermostat controls your furnace. Ensure it is set correctly. First, check if the thermostat is set to heat mode. If it is in cool mode, the furnace will not start.

Next, verify the temperature setting. Set it at least five degrees higher than the current room temperature. This ensures the furnace has a clear signal to turn on.

Look at the thermostat display. If it is blank, replace the batteries. A weak battery can cause the thermostat to malfunction.

Power Supply

Your furnace needs power to operate. Ensure the power switch is turned on. The switch is usually located near the furnace on the wall.

Check the circuit breaker or fuse box. A tripped breaker or blown fuse can cut off power. Reset the breaker or replace the fuse if necessary.

Inspect the power cord. Ensure it is plugged in securely. Look for any signs of damage or wear.

If your furnace has a power indicator light, ensure it is on. A lit indicator confirms power is reaching the furnace.

Check Action
Thermostat Mode Set to Heat
Temperature Setting Set Higher than Room Temperature
Thermostat Display Replace Batteries if Blank
Power Switch Ensure it is On
Circuit Breaker Reset if Tripped
Power Cord Check for Secure Connection
Power Indicator Light Ensure it is Lit

Furnace Not Igniting

When your Coleman Evcon furnace fails to ignite, it can disrupt your home’s comfort. Understanding the common issues can help you troubleshoot effectively. Below are some frequent causes and solutions.

Pilot Light Problems

The pilot light ignites the furnace burners. If it’s not working, your furnace won’t start.

  • Check the Pilot Light: Ensure it’s lit. If not, relight it.
  • Inspect for Obstructions: Dust or debris can block the pilot light.
  • Thermocouple Issues: The thermocouple might be faulty. Replace it if needed.

Ignitor Faults

The ignitor creates the spark to ignite the gas. A faulty ignitor means no heat.

Common Issues Solutions
Dirty Ignitor Clean the ignitor gently with a soft brush.
Cracked Ignitor Replace the ignitor if it’s cracked or broken.
Electrical Issues Check wiring connections. Ensure they are secure.

Address these common issues to get your furnace igniting again. Regular maintenance can prevent these problems.

Blower Motor Problems

Experiencing issues with your Coleman Evcon furnace? A common problem is the blower motor. The blower motor is crucial for circulating warm air through your home. If it’s not working properly, your furnace can’t function efficiently.

Motor Not Running

If your blower motor is not running, start by checking the power source. Make sure the furnace is plugged in and the circuit breaker is not tripped. Inspect the thermostat to ensure it’s set to the correct temperature.

Follow these steps:

  1. Verify power supply to the furnace.
  2. Ensure thermostat settings are correct.
  3. Check for any blown fuses in the furnace.
  4. Look for any visible wiring issues.

If these steps don’t resolve the issue, the problem might be internal. In such cases, it’s best to call a professional technician.

Strange Noises

Strange noises from the blower motor can indicate various issues. Listen for any unusual sounds like grinding, squealing, or banging.

Common causes include:

  • Loose parts: Check for any loose components and tighten them.
  • Debris: Ensure there’s no debris obstructing the motor.
  • Worn bearings: Bearings may need lubrication or replacement.

Addressing these noises early can prevent more serious damage. Regular maintenance helps keep your blower motor running smoothly.

Use this troubleshooting table to diagnose noises:

Noise Type Possible Cause Solution
Grinding Worn bearings Lubricate or replace bearings
Squealing Loose belt Tighten or replace belt
Banging Loose parts Tighten components

Proper maintenance and timely repairs ensure your Coleman Evcon furnace operates efficiently.

Airflow Issues

Airflow issues can cause your Coleman Evcon Furnace to work poorly. These issues lead to uneven heating and higher energy bills. Let’s look at two common airflow problems: Clogged Filters and Blocked Vents.

Clogged Filters

Clogged filters block the airflow in your furnace. This makes your furnace work harder. It also reduces the lifespan of your furnace.

To check for clogged filters, follow these steps:

  1. Turn off your furnace.
  2. Locate the filter compartment.
  3. Remove the filter.
  4. Inspect the filter for dirt and debris.
  5. If dirty, replace the filter with a new one.

It’s best to check your filters every month. This helps to maintain good airflow.

Blocked Vents

Blocked vents can stop warm air from spreading in your home. This can make some rooms colder than others.

To fix blocked vents:

  • Ensure furniture is not blocking the vents.
  • Check for dust or debris inside the vents.
  • Clean the vents using a vacuum cleaner.

Keeping vents clear allows for proper airflow. This helps your furnace work efficiently.

Here is a table summarizing the steps:

Issue Steps
Clogged Filters
  1. Turn off furnace
  2. Locate filter
  3. Remove filter
  4. Inspect filter
  5. Replace if dirty
Blocked Vents
  • Move furniture
  • Check for debris
  • Clean with vacuum

Thermostat Malfunctions

A malfunctioning thermostat can cause your Coleman Evcon furnace to stop working. This section covers common thermostat issues. Learn about calibration errors and wiring problems. Fix these problems to restore your furnace’s functionality.

Calibration Errors

Calibration errors can lead to incorrect temperature readings. This affects the furnace’s performance. To check for calibration errors, use a thermometer. Compare the thermostat’s reading with the thermometer’s. If the readings differ, the thermostat needs recalibration.

Follow these steps to recalibrate:

  • Turn off the furnace.
  • Remove the thermostat cover.
  • Locate the calibration screw.
  • Use a screwdriver to adjust the screw.
  • Recheck the temperature readings.

If recalibration fails, replace the thermostat. An accurate thermostat ensures your furnace runs efficiently.

Wiring Problems

Wiring problems can disrupt the thermostat’s connection to the furnace. Inspect the thermostat wires for any signs of damage. Look for frayed or broken wires. Ensure all connections are tight and secure.

Here are common wiring issues:

  1. Loose connections
  2. Corroded wires
  3. Incorrect wiring setup

Use the furnace’s manual to verify the wiring layout. If unsure, contact a professional technician. Proper wiring is crucial for thermostat functionality.

Below is a table summarizing common thermostat wiring problems and their solutions:

Problem Solution
Loose connections Tighten the wire connections
Corroded wires Clean or replace the wires
Incorrect wiring setup Refer to the manual for correct setup

Gas Supply Concerns

Facing issues with your Coleman Evcon furnace? Gas supply problems might be the cause. Addressing these concerns ensures your furnace works efficiently. This section focuses on troubleshooting gas supply issues, including gas valve problems and supply line checks.

Gas Valve Issues

The gas valve controls the gas flow to the furnace. A malfunctioning valve can disrupt this flow. Ensure the valve is set to the “on” position. If the valve is open but there’s no gas flow, the valve might be faulty.

Here’s how to check the gas valve:

  • Locate the gas valve near the furnace.
  • Ensure the valve is not obstructed.
  • Check for any unusual sounds.
  • Test the valve with a multimeter for continuity.

If the valve shows no continuity, replace it immediately. This ensures a continuous gas supply to the furnace.

Supply Line Checks

The supply line delivers gas from the main supply to the furnace. Issues in this line can halt the gas flow. Inspect the supply line regularly for any visible damage.

Steps to inspect the supply line:

  1. Turn off the gas supply.
  2. Check the entire line for cracks or leaks.
  3. Use a soapy water solution to find leaks.
  4. Apply the solution to the line and watch for bubbles.

If bubbles appear, there’s a leak. Repair or replace the damaged section immediately. A secure supply line ensures uninterrupted gas flow.

Regular checks and timely repairs maintain your Coleman Evcon furnace’s efficiency. Address gas supply concerns promptly to enjoy a warm, comfortable home.

Regular Maintenance

Regular maintenance of your Coleman Evcon furnace ensures its longevity and efficiency. By keeping up with maintenance, you can avoid costly repairs and stay warm during winter.

Cleaning Components

Cleaning the components of your furnace is essential for its performance. Dust and debris can clog the system and reduce efficiency. Here’s a simple step-by-step guide:

  1. Turn off the power to the furnace.
  2. Remove the access panel to expose the internal components.
  3. Use a soft brush to clean the blower assembly.
  4. Vacuum around the motor and burners to remove dust.
  5. Check and clean the flame sensor with a soft cloth.

Professional Inspections

Scheduling regular inspections by a professional technician is vital. They can identify issues that are not visible to the untrained eye. Here are some benefits:

  • Ensure the furnace is operating safely.
  • Detect early signs of wear and tear.
  • Optimize the furnace for energy efficiency.
  • Prolong the lifespan of your furnace.
Inspection Area Purpose Frequency
Heat Exchanger Check for cracks or damage Annually
Thermostat Ensure accurate temperature control Annually
Electrical Connections Check for secure and tight connections Annually
Gas Pressure Ensure correct pressure levels Annually

Maintaining your Coleman Evcon furnace with regular cleaning and professional inspections can save money and keep your home warm.

Frequently Asked Questions

Why Is My Coleman Evcon Furnace Not Igniting?

The igniter may be faulty or dirty, preventing ignition.

How Do I Reset My Coleman Evcon Furnace?

Turn off the power, wait 10 seconds, then turn it back on.

What Causes Coleman Evcon Furnace To Blow Cold Air?

The thermostat could be set incorrectly or there might be a problem with the pilot light.

How Often Should I Service My Coleman Evcon Furnace?

Service your Coleman Evcon furnace annually to ensure optimal performance and safety.

Why Is My Coleman Evcon Furnace Making Noise?

Noises may indicate loose parts, a dirty burner, or a failing motor.

Conclusion

Regular maintenance and troubleshooting can keep your Coleman Evcon furnace running smoothly. Addressing issues early prevents costly repairs. Follow the steps outlined to ensure efficiency and longevity. Don’t hesitate to consult a professional if needed. A well-maintained furnace guarantees comfort and peace of mind during colder months.

Leave a Comment